Whirlpool WVW53UC6LS Installatie-instructies en gebruiks- en onderhoudshandleiding - Pagina 8

Blader online of download pdf Installatie-instructies en gebruiks- en onderhoudshandleiding voor {categorie_naam} Whirlpool WVW53UC6LS. Whirlpool WVW53UC6LS 24 pagina's. 30" and 36" (76.2 and 91.4 cm) wall‑mount canopy

Whirlpool WVW53UC6LS Installatie-instructies en gebruiks- en onderhoudshandleiding

Connect Vent System

1. Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.

Install Range Hood

NOTE: Remove protective film from range hood and metal filters.
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
8
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket with
2. Measure from the bottom of the air deflector to the bottom
B
3. Cut the duct to the measured size "X."
4. Remove the air deflector.
C
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over
7. Reassemble the air deflector to the duct cover bracket
8. Seal connections with vent clamps.
2 assembly screws provided with the Recirculation Kit.
B
A. Vent cover bracket
B. Assembly screws
C. Deflector
of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
the exhaust outlet from the hood.
with the 2 assembly screws.
A
B
C
A
C
X