HEATER LOCATION
The healer is for outdoor use only (see attached
diagrammatical representations of ouldoor areas). Do not use it for
indoors or in an enclosed area, Always ensure that adequate fresh air
ventilation is provided.
Do not use the heater indoors,
Do not use the heater in basements or enclosed areas,
Always maintain 48 '' clearance from combustible materials, or
minimum 24 " top 24 " sides.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
To protect heater from strong wind, anchor the base securely to the
ground with screws.
GAS REQUIREMENTS
Use propane or LPG only.
The heater is designed for use with 20-lbs, cylinder.
The appliance requires approved gas hose in 47 11 length and a regulator.
Regulator maximum inlet pressure must not exceed 690 kPa (100 PSI).
Regulator outlet pressure to be 28 mbar (2.8 kPa or 11" W.C.),
The hose and regulator assembly must conform to local standard codes.
The installation must conform to local codes, or in Ihe absence of local codes, to the standard for the
storage and handling of liquid petroleum gases,
A dented, rusted or damaged gas cylinder may be hazardous and should be checked by your gas
supplier. Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor wllhdrawal from the operating cylinder.
Avoid twisting the flexible tubes and hoses,
Never connect an unregulated gas cylinder to the healer,
Disconnect the gas cylinder when the heater is not in use,
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipmenl. A complete gas tightness
check must be performed at Ihe installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater. The healer must be checked with a full cylinder.
1.
Make sure the safety control valve Is in the OFF position.
2.
Make a soapy water solution of one part liquid detergent and one
part water, The soapy water solution can be applied with a spray
bottle, brush or rag to all gas connections. Soap bubbles will appear
in case of a leak.
WARNING
Never leak test while smoking.
-
2
-