Alcons LR18/90i Gebruikershandleiding - Pagina 13

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Alcons LR18/90i. Alcons LR18/90i 18 pagina's. Compact installation line-array module

Alcons LR18/90i Gebruikershandleiding
5. Array configurations ___________________________________________
LR18i array assembling
Required tools: Allan key wrench 5mm, thin 13mm wrench, long 13mm
combination wrench and torque wrench 5-20Nm.
Start by mounting GRD18i(1) onto the top LR18i cabinet. Use the
supplied locating bolts and black locking nuts for the front couplers(2).
Align the A/B hole with the "A" hole in the angle frame(5) with the collar
bolt(6) and the 0,5°/hole GRD18i to the 0° hole of the GRD18i. Pin the
long M8 bolt and slide the black bushing onto the bolt end. Lock the
connection with the black locking nut.
Hoist the GRD18i and cabinet and tighten the bolt connections firmly.
Make the first inter-cabinet connection. Align the front coupler holes and
pin with the locating bolt and locking nuts. Due to the tight space, a thin
wrench is preferred. A "long nose plier" can also be used, to align and
screw the nut onto the locating bolt ->15Nm.
Make the correct angle connection. These are stated on the angle
frame. Apply thread locking fluid on the collar bolts(6) for the angle
connection. Raise the array and tighten up the bolt connections->15Nm.
Repeat these steps for the remaining cabinets.
When the assembled array has been raised, check all bolt connections.
13
Rigging manual LR18i Rev. 1.1