Alde Compact 3020 HE Gebruiksaanwijzing - Pagina 10

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Alde Compact 3020 HE. Alde Compact 3020 HE 19 pagina's.
Ook voor Alde Compact 3020 HE: Gebruiksaanwijzing & installatiehandleiding (8 pagina's), Wijziging van de installatie-instructies (4 pagina's)

Alde Compact 3020 HE Gebruiksaanwijzing
17. Circulation pump settings
Pump selection: Choice of pump.
*12 V pump. Variable adjustment of
pump capacity is achieved using a
potentiometer on the rear of the pump
(1-5); normal mode is 2, which works in
most cases. Mounted on the boiler.
*PWM controlled 12 V pump. This is a
variable speed controlled pump that
can be set to five different modes
(levels 1-5) via the panel; normal mode
is 2, which works in most cases.
Mounted on the boiler.
*Extra 12 V pump, often located in the
expansion tank.
Pump settings:
Cont: The pump is in constant opera-
tion.
NB. This function limits the supply of
hot water, particularly when there is a
low
heating requirement.
Therm: The pump is controlled by the
room sensor. This is the normal mode
for heat and hot water.
18. Automatic boiler start
Starting the boiler at a certain time/
on a certain day. The boiler will be on
every week during the time set, until
the function is deactivated. For auto-
matic start to function, the boiler must
be turned off.
19. Sound
Audible signals in various situations:
Turn the button sound on and off.
Audible signal on reaching hot
water temperature when Alde Flow*
is installed and more hot water is
selected.
Audible signal on "Gas Failure".
Audible signal on LPG bottle chan
geover if a DuoControl* isinstalled
and activated in "Installed Accesso
ries", see section 11.
20. Reset
Pressing Reset resets the panel to its
factory settings.
NB. Settings made in installed fun-
ctions are not deleted.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
10
manufacturer's instructions.
21. External start
The function is used when starting
the boiler from outside. When exter-
nal start has been activated the panel
must be turned off. External start has
three modes, Off, Ext and 230 V. In the
Off mode, the function is turned off.
*Ext. The function is used when star-
ting the boiler through an external sig-
nal. When the Ext. function has been
activated, the control panel must be
turned off, but 12 V should be connec-
ted. The parameters/functions that the
boiler is to have when it starts must
be set before turning off the control
panel.
NB.Using this function requires instal-
lation of an accessory that can use
external start.230 V. The function is
used to start the boiler by connecting
230 V to the vehicle.
When the 230 V function has been
activated the control panel must be
turned off, but
12 V should be connected. The para-
meters/functions that the boiler is to
have when it starts must be set before
turning off the control panel (230 V
connected). Certain vehicles can be
equipped with an individual solution
(*winter connection).
22. Language
Switch between different langu-
ages. Available languages are English,
French and German.
However, the service menu is only avai-
lable in English(see section 8).
23. Installed functions
The accessories that are installed are
activated here (see section 11).
24. Service menu.
This contains the following, amongst
others:
Glycol temperature
Domestic hot water temperature
12 V power to the boiler
To exit the tools menu, press Return or
Menu.