Xerox DocuColor 40/30 Family Digital Color Production System

ENVIRONMENTAL AND ELECTRICAL REQUIREMENTS

DocuColor 40/30
Environmental
Temperature ( F)
Relative Humidity (% RH)
Altitude (Feet above sea level)
Better performance is achieved when conditions are maintained between 65 - 75 F and 25 - 60% RH.
High altitude performance (above 5,000 feet) has not been certified.
Max. Power Consumption
Printing: 2.6 kW or less in full system
Standby: 1.8 kW
Current loads:
220 VAC assumed
Printing: 11.8 Amps
Standby: 8.2 Amps
Electrical Specifications:
Single phase - Two wire plus safety ground
Current Service - 30 Amps (Sole Use)
Frequency - 50/60 Hz
Accessories
Electrical Specifications:
The following power requirements apply to the Stacker/Stapler, High Capacity Feeder, and the ASF 40 System:
115 VAC for 60Hz or 220 VAC for 50Hz installations (90 to 256VAC in both 50Hz and 60Hz installations.)
Note: Power cords are provided with Stacker/Stapler, HCF, ASF 40, and Accumulator/Rotator.
Note: DocuColor 40/30, Stacker/Stapler, HCF and ASF 40 and the ASF 40 Accumulator/Rotator require separate power sources.
Note: ASF 40 and ASF 40 Trimmer use the same power source.
Minimum
50 F (10 C)
20%
None
8875 BTU / Hr
6143 BTU / Hr
2.6 kVA (approx.)
1.8 kVA (approx.)
14
Maximum
90 F (32 C)
85%
5,000 Feet
Version 6.0
09/08/99