INSTALLATION DETAILS
•
Hot and cold-water inlet pressures should be equal
•
Inlet pressure 150 – 500 Kpa. Note New Building Regulation –
500Kpa maximum operating pressure at any outlet within the
building (Refer AS/NZS 3500.1:2003 Clause 3.34)
•
Maximum water temperature 75⁰C
•
May not be suitable for use with gravity-fed water heaters, low
and unequal pressure networks, instantaneous water heaters,
tempering valves and thermostatic mixing valves
•
Care taken to protect the flow controllers from blockage due to
foreign debris and damage due to male connecting threads
•
If it is possible for backflow to occur with the handset, then a
double check valve will need to be installed as required by
AS/NZS 3500 Plumbing & Drainage Code