Alderon Industries 2000275 Gebruikershandleiding - Pagina 11

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Alderon Industries 2000275. Alderon Industries 2000275 16 pagina's. Plastic cable weight control and pump switches

Alderon Industries 2000275 Gebruikershandleiding

Troubleshooting

PROBLEM
Float switch cable is slipping
Cable weight is not accepting cable clip Cable clip not properly aligned with slot
Float switch is not activating
PROBABLE CAUSE
Cable clip is not properly fastened
Float switch cable is not the correct
gauge (AWG)
on cable weight
Float switch cable is not the correct
gauge (AWG)
Obstruction preventing the float switch
from tilting to the proper activation angle
Incorrect installation of float switch
Alderon Industries™ - Leading Edge Control Products | 11
Plastic Cable Weight - USER GUIDE
SOLUTION
Make sure cable clip is secured in the
correct notch for size of the float switch
cable (refer to Tightening Cable Clip
step 1 on page 7)
Measure float switch cable diameter to
ensure it's compatible, minimum size
of 0.28 inches (18 AWG) and maximum
size of 0.39 inches (14 AWG)
Align cable clip with grooves of the slot
on cable weight
Measure float switch cable diameter to
ensure it's compatible, minimum size
of 0.28 inches (18 AWG) and maximum
size of 0.39 inches (14 AWG)
Move both the float switch and the
mounted float bracket to a location in
the monitoring area free of obstructions
or remove obstruction from monitoring
area if possible
Refer to instructions that came with the
float switch for recommended tether
length guides, mounting location, total
operating angle, and activation levels for
normal operation