Alderon Industries VertiMAC VM13 Series Gebruikershandleiding - Pagina 6

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Alderon Industries VertiMAC VM13 Series. Alderon Industries VertiMAC VM13 Series 20 pagina's. Pump switch

VertiMAC™ Pump Switch - USER GUIDE

Installation

DISCONNECT ALL POWER SOURCES WHEN INSTALLING OR SERVICING THIS PRODUCT. FAILURE TO
TURN OFF ALL POWER SOURCES COULD RESULT IN SERIOUS INJURY OR DEATH.

Pump Differential

STEP 1: DETERMINING PUMP DIFFERENTIAL
Determine the pump differential and move the rubber grommet on the actuator rod to achieve the desired range. After the pump
switch installation is complete, perform testing to achieve actual pumping differential.
Maximum Differential: Move the rubber grommet to the bottom of the actuator rod to create the largest pump differential, which
is six inches (6.0").
Minimum Differential: Move the float and rubber grommet to the top of the actuator rod to create the smallest pump differential,
which is one and a half inches (1.5").
Note: Leave approximately one eighth inch (1/8") of space between the rubber grommet and the bottom of the actuator rod to
achieve the maximum differential. Placing the rubber grommet at the bottom of the rod could cause the grommet and float to
separate from the actuator rod.
(Pump Activated)
Maximum (6.0")
Pump Differential
6 | Alderon Industries™ - Leading Edge Control Products
(Pump Deactivated)
(Pump Activated)
Minimum (1.5")
Pump Differential
(Pump Deactivated)