Error Message No Power
nP is displayed when there is no power to the system. If the message
is displayed when the system is powered, check the wiring from the
thermostat to Wiring Hub and the Wiring Hub to the system for errors.
Upstairs
Airflow %
Auto
Downstairs
Day
Tu
AM
MENU
MODE
Press the touchscreen with your fingertip only, using a firm touch. Do not use a sharp object such as a
pen or pencil.
INSTALLER OPTIONS
Option
Description
01
Equipment Type
Heat Pump Type
02
03
Outdoor Temperature Fossil fuel (OBP)
04
Compressor Stages
05
Heating Stages
06
Fan Operation.
(Only displayed if GE selected)
Compressor Minimum Off Time (minutes).
07
08
Gas Minimum Off Time (minutes).
09
Minimum Run Time (minutes).
On-Off Temperature Differential
10
0 Cooling On 1 above setpoint, Off at setpoint. Heating On1 below setpoint, Off at setpoint.
1 Cooling On 1 above setpoint, Off .5 below setpoint. Heating On1 below setpoint, Off .5 above setpoint.
2 Cooling On 1 above setpoint, Off 1 below setpoint. Heating On1 below setpoint, Off 1 above setpoint.
11
Smart Recovery.
12
Vacant Heating Setpoint.
13
Vacant Cooling Setpoint.
14
Calibrate Downstairs Sensor
15
Calibrate Upstairs Sensor.
16
Airflow Update Time
17
Night Level LCD Backlight
18
Airflow Control On or Off
Up Stage Time
19
20
Maximum Upstairs Airflow in Heating.
21
Maximum Upstairs Airflow in Cooling.
22
Maximum Downstairs Airflow in Heating.
Maximum Downstairs Airflow in Cooling.
23
24
Maximum Temperature Difference Between
Upstairs and Downstairs.
25
Home Number
26
Thermostat Location
27
Factory Restore
Cool
Set To
Schedule
Inside
COOL
SYSTEM
AUTO
FAN
(Only displayed if HP selected)
o
o
o
o
o
Display
Range
GE or HP
HPt
Co or dF
O8P
35 to 55F
CPr
0 or 1 (GE), 0 to 2 (HP)
HtG
0, 1 or 2
FAn
GA(Up) or EL(Down)
0 to 9
COt
HOt
0 to 9
0 to 9
r n t
o
O O
0, 1 or 2
o
o
o
S r
0n(Up) or Off(Down)
V A C
+ Heat
44 to 75
V A C
+ Cool
74 to 95
C A L
+/- 5
C A L
+/- 5
A F t
1 to 20 minutes
+ Night
BL
On(Up) or Off(Down)
AFC
On(Up) or Off(Down)
USt
0 to 30 minutes
HAF+Heat
100 to 155%
CAF+Cool
100 to 155%
HAF+Heat
100 to 155%
CAF+Cool
100 to 145%
diF
0 to 10
Home
1 to 8
tLo
dS or uS
Fr
No(Next) or Yes(Enter) + UP
4
Default
GE
Co
40F
1 (GE), 2 (HP)
1
GA
2
0
1
1
o
o
Off
65
80
NA
NA
2
On
On
5
150%
140%
150%
140%
2
1
dS
NA