2.2.1 XG bulk dump

This message sets XG-related parameters. Unlike parameter change messages, a single
message can modify multiple parameters. The message format is as follows.
F0H
Exclusive status
11110000
43H
YAMAHA ID
01000011
0NH
N:Device Number
0000nnnn
01001100
4CH
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
GGH
Address High
0ggggggg
MMH
Address Mid
0mmmmmmm
LLH
Address Low
0lllllll
0vvvvvvv
VVH
Data
:
:
KKH
Check-sum
0kkkkkkk
F7H
End of Exclusive
11110111
Address and Byte Count are given in tables 1-n. Byte Count is indicated by the total
size of the Data in tables 1-n.
Bulk dump and dump request messages are received when the beginning of the block
is specified as the 'Address'.
'Block' indicates the unit of the data string that is indicated in tables 1-n as 'Total size'.
Check sum is the value that produces a lower 7 bits of 0 when the Start Address, Byte
Count, Data, and the Check-sum itself are added.

2.2.1.1 XG System bulk dump

This message sets the XG SYSTEM block (refer to tables <1 -1>, <1 - 2>).
< Table 1-1 >
Parameter Base Address
MODEL ID = 4C
Parameter
Description
Address
(H)
(M)
(L)
XG SYSTEM
00
00
00
System
00
00
7D
Drum setup Reset
00
00
7E
XG System On
00
00
7F
All Parameter Reset
EFFECT 1
02
01
00
Effect1(Reverb,Chorus,Variation)
MULTI PART
08
00
00
Multi Part 1
:
:
:
:
08
0F
00
Multi Part 16
DRUM
30
0D
00
Drum Setup 1
31
0D
00
Drum Setup 2
< Table 1-2 >
MIDI Parameter Change table ( XG SYSTEM )
Address
Size
Data
(H)
(H)
(H)
00 00 00
4
00 - 0F
01
00 - 0F
02
00 - 0F
03
00 - 0F
04
1
00 - 7F
05
1
06
1
28 - 58
7D
1
N
7E
1
00
7F
1
00
TOTAL SIZE
07
Address
3n
3n
3n
Parameter
MASTER TUNE
MASTER VOLUME
not used
TRANSPOSE
DRUM SETUP RESET
XG SYSTEM ON
ALL PARAMETER RESET
2.2.1.2 Multi Effect1 bulk dump
This message sets the MULTI EFFECT1 block (refer to tables <1 - 1>,
<1 - 3>).
2.2.1.3 Multi Part bulk dump
This message sets the MULTI PART block (refer to tables <1 - 1>, <1 - 4>).
2.2.1.4 Drums Setup bulk dump
This message sets the DRUMS SETUP block (refer to tables <1 - 1>, <1 - 5>).

3. Realtime messages

3.1 Active sensing

a) Transmission
not transmitted.
b) Receive
Once FE has been received, failure to receive any MIDI message for an interval
longer than approximately 300 msec will cause processing to be performed as if
ALL SOUND OFF, ALL NOTE OFF, and RESET ALL CONTROLLERS mes-
sages were received, and the unit will reset to a condition in which FE was never
received.
Parameter
0D
00
note number 13
0E
00
note number 14
:
:
5B
00
note number 91
Description
-102.4...0...+102.3[cent]
1st bit3-0 bit15-12
2nd bit3-0 bit11-8
3rd bit3-0 bit7-4
4th bit3-0 bit3-0
0...127
-24...0...+24[semitones]
N: Drum setup number(0,1)
00=XG system ON (receive only)
00=ON (receive only)
MIDI Data Format
Default value
(H)
00 04 00 00
7F
40
--
--
--
CLP-970