Installation Instructions
FEATURES
APPLICATIONS Decorative Lighting
VOLTAGE 24V or 120V
LAMP TYPE LEDs
DIMMING 120V: Not Dimmable
24V: 0-10V Dimming (TRA-E)
MAXIMUM RUN 32' (24V), 150' (120V)
FINISH White
FEED Power Connector
MOUNTING U-Channel or Mounting Clip
LISTING Dry or Wet Location
WARNING
When using NLED for any application, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and
personal injury. NLED must be installed in accordance with the NEC or
CEC as applicable.
• Do not exceed maximum length per circuit. Each maximum run requires
additional power feed from the transformer
• Do not cover NLED as the covering may cause it to overheat, melt,
or ignite.
• Do not install NLED in hazardous locations or closer than 6 inches
from any curtain or similar combustible material.
• Do not install NLED in places where it is subject to continuous
flexing.
• Do not install wet location model in areas where water will collect.
i
!
CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
[email protected] \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
NLED 24V DIMMING PROTOCOL (0-10V)
NLED is available in 120 or 277 volts with a dimmable remote driver. The
remote driver is available with 0-10V dimming capabilities.
The following applies to 0-10V dimming interfaces. A 0-10v fluorescent
dimmer will not dim the LEDs.
Technical Requirements For Control Equipment
• The output current level of the dimmable driver is controlled by DC voltage
(0-10V) applied to the control terminals (blue and white). The light output of
LEDs is controlled by the amount of output current from the dimmable driver.
• The control device must be capable of sinking a DC current flow from the driver.
The maximum amount under any condition is 500 microamps (uA) per driver.
• The control terminals of the dimmable driver are isolated from the power lines
and are suitable for use as Class 2 wiring. Multiple drivers are desired for use
with same control device, the control terminals may be connected in parallel in a
bus configuration.
• Since the control bus is Class 2 wiring, all control devices that are connected
to the power line must have proper isolation between the power line and the
control terminals/bus.
• The control device, which intends to control more than one dimmable driver,
must be capable of sinking the total current supplied to control bus by the drivers.
• If the control terminals/bus is shorted in any case, the current on the control
terminals/bus will be 500 microamps (uA) per driver maximum.
• If the control terminals are opened, the voltage on the control terminals will them
be 10V ± 0.5 volt. As a result, dimmable driver supplies maximum output current
to LEDs under this condition.
• The driver is intended for use with control voltages between 0 and 10 VDC. The
control equipment must not impose a voltage greater than 11 V peak maximum
on the driver control terminals.
• Order transformer with TRA-E prefix.
Click here for list of
electronic transformers
(TRA-E) 0-10V Dimming
i
2 of 10
NLED
Overview
(0-10V Protocol)