Yamaha YPT-340 Servicehandleiding - Pagina 28

Blader online of download pdf Servicehandleiding voor {categorie_naam} Yamaha YPT-340. Yamaha YPT-340 49 pagina's. Midi reference
Ook voor Yamaha YPT-340: Referentie (3 pagina's)

PSR-E343/PSR-E344/YPT-340
TEST
LCD display
No.
057: FRomChk2
57
060: Factory
60
061: TestExit
61

Other Tests

Popping Noise Check
Connect the oscilloscope to the L/R of the [PHONES/OUTPUT] jack and turn on and then off the [STANDBY/ON] switch. Make
sure that popping noise level is 1.0 Vp-p or less, and that no abnormal sound or popping noise is output from the speakers.
Noise Level Check
Connect the level meter (with JIS-C filter) to the L/R of the [PHONES/OUTPUT] jack. (33 Ω load)
Set the [MASTER VOLUME] to the maximum level and check the noise level. Do not insert any plugs to [AUX-IN] jack.
· PHONES L, R: –75 dBu or less
Battery Charging Check
Connect the AC adapter to the [DC IN] jack.
Confi rm that the unit shall be performed normally, and no voltage is generated between spring terminal A - B.
28
Test descriptions, judging conditions, etc.
Checks the FROM connected to the CPU bus. (Full address)
Make sure that "FRom OK" is displayed on the LCD.
It will take about 100 seconds for the check.
Initializes the entire backup area to reset to the factory default.
"Fact --" is displayed on the LCD during the factory set.
"Fact End" is displayed on the LCD when the factory set is finished.
Do not turn off the power during this process.
This will leave the test program, reset the system and change to the play mode.
Do not turn off the power until the main screen is displayed.