Yamaha Clavinova CLP-970 Naslagwerk - Pagina 13

Blader online of download pdf Naslagwerk voor {categorie_naam} Yamaha Clavinova CLP-970. Yamaha Clavinova CLP-970 37 pagina's. Yamaha digital piano owner's manual
Ook voor Yamaha Clavinova CLP-970: (Japanse) gebruikershandleiding (24 pagina's)

Yamaha Clavinova CLP-970 Naslagwerk

Effect Parameter List

TIP
HALL1,HALL2
ROOM1,ROOM2,ROOM3
STAGE1,STAGE2
PLATE (reverb, variation block)
No.
Parameter
Display
1 Reverb Time
0.3 - 30.0s
2 Diffusion
0 - 10
3 Initial Delay
0.1 - 99.3ms
4 HPF Cutoff
Thru - 8.0kHz
5 LPF Cutoff
1.0k - Thru
6
7
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11 Rev Delay
0 - 63
12 Density
0 - 3
13 Er/Rev Balance
E63>R - E=R - E<R63
14
15 Feedback Level
-63 - +63
16
WHITE ROOM
TUNNEL
BASEMENT (reverb block)
No.
Parameter
Display
1 Reverb Time
0.3 - 30.0s
2 Diffusion
0 - 10
3 Initial Delay
0.1 - 99.3ms
4 HPF Cutoff
Thru - 8.0kHz
5 LPF Cutoff
1.0k - Thru
6 Width
0.5 - 10.2m
7 Heigt
0.5 - 20.2m
8 Depth
0.5 - 30.2m
9 Wall Vary
0 - 30
10
11 Rev Delay
0 - 63
12 Density
0 - 3
13 Er/Rev Balance
E63>R - E=R - E<R63
14
15 Feedback Level
-63 - +63
16
DELAY L,C,R (variation block)
No.
Parameter
Display
1 Lch Delay
0.1 - 715.0ms (variation block)
2 Rch Delay
0.1 - 715.0ms (variation block)
3 Cch Delay
0.1 - 715.0ms (variation block)
4 Feedback Delay
0.1 - 715.0ms (variation block)
5 Feedback Level
-63 - +63
6 Cch Level
0 - 127
7 High Damp
0.1 - 1.0
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11
12
13 EQ Low Frequency 50Hz - 2.0kHz
14 EQ Low Gain
-12 - +12dB
15 EQ High Frequency 500Hz - 16.0kHz
16 EQ High Gain
-12 - +12dB
DELAY L,R (variation block)
No.
Parameter
Display
1 Lch Delay
0.1 - 715.0ms (variation block)
2 Rch Delay
0.1 - 715.0ms (variation block)
3 Feedback Delay 1
0.1 - 715.0ms (variation block)
4 Feedback Delay 2
0.1 - 715.0ms (variation block)
5 Feedback Level
-63 - +63
6 High Damp
0.1 - 1.0
7
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11
12
13 EQ Low Frequency 50Hz - 2.0kHz
14 EQ Low Gain
-12 - +12dB
15 EQ High Frequency 500Hz - 16.0kHz
16 EQ High Gain
-12 - +12dB
Parameters marked with a
controller 1) etc. However, this is valid only for a Variation effect (when selected for Insertion).
Value
See Table
Control
0 - 69
table#4
0 - 10
0 - 63
table#5
0 - 52
table#3
34 - 60
table#3
1 - 127
0 - 63
table#5
0 - 3
1 - 127
1 - 127
Value
See Table
Control
0 - 69
table#4
0 - 10
0 - 63
table#5
0 - 52
table#3
34 - 60
table#3
0 - 37
table#8
0 - 73
table#8
0 - 104
table#8
0 - 30
0 - 63
table#5
0 - 3
1 - 127
1 - 127
Value
See Table
Control
1 - 7150
1 - 7150
1 - 7150
1 - 7150
1 - 127
0 - 127
1 - 10
1 - 127
8 - 40
table#3
52 - 76
28 - 58
table#3
52 - 76
Value
See Table
Control
1 - 7150
1 - 7150
1 - 7150
1 - 7150
1 - 127
1 - 10
1 - 127
8 - 40
table#3
52 - 76
28 - 58
table#3
52 - 76
in the "Control" column can be controlled from an AC1 (assignable

ECHO (variation block)

No.
Parameter
1 Lch Delay1
0.1 - 355.0ms (variation block) 1 - 3550
2 Lch Feedback Level -63 - +63
3 Rch Delay1
0.1 - 355.0ms (variation block) 1 - 3550
4 Rch Feedback Level -63 - +63
5 High Damp
0.1 - 1.0
6 Lch Delay2
0.1 - 355.0ms (variation block)
7 Rch Delay2
0.1 - 355.0ms (variation block)
8 Delay2 Level
0 - 127
9
10 Dry/Wet
D63>W - D=W - D<W63
11
12
13 EQ Low Frequency 50Hz - 2.0kHz
14 EQ Low Gain
-12 - +12dB
15 EQ High Frequency 500Hz - 16.0kHz
16 EQ High Gain
-12 - +12dB

CROSS DELAY (variation block)

No.
Parameter
1 L->R Delay
0.1 - 355.0ms (variation block) 1 - 3550
2 R->L Delay
0.1 - 355.0ms (variation block) 1 - 3550
3 Feedback Level
-63 - +63
4 Input Select
L,R,L&R
5 High Damp
0.1 - 1.0
6
7
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11
12
13 EQ Low Frequency 50Hz - 2.0kHz
14 EQ Low Gain
-12 - +12dB
15 EQ High Frequency 500Hz - 16.0kHz
16 EQ High Gain
-12 - +12dB

EARLY REF1,EARLY REF2(variation block)

No.
Parameter
1 Type
S-H, L-H, Rdm, Rvs, Plt, Spr
2 Room Size
0.1 - 7.0
3 Diffusion
0 - 10
4 Initial Delay
0.1 - 99.3ms
5 Feedback Level
-63 - +63
6 HPF Cutoff
Thru - 8.0kHz
7 LPF Cutoff
1.0k - Thru
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11 Liveness
0 - 10
12 Density
0 - 3
13 High Damp
0.1 - 1.0
14
15
16
GATE REVERB
REVERSE GATE (variation block)
No.
Parameter
1 Type
TypeA,TypeB
2 Room Size
0.1 - 7.0
3 Diffusion
0 - 10
4 Initial Delay
0.1 - 99.3ms
5 Feedback Level
-63 - +63
6 HPF Cutoff
Thru - 8.0kHz
7 LPF Cutoff
1.0k - Thru
8
9
10 Dry/Wet
D63>W - D=W - D<W63
11 Liveness
0 - 10
12 Density
0 - 3
13 High Damp
0.1 - 1.0
14
15
16
Display
Value
See Table
1 - 127
1 - 127
1 - 10
1 - 3550
1 - 3550
0 - 127
1 - 127
8 - 40
table#3
52 - 76
28 - 58
table#3
52 - 76
Display
Value
See Table
1 - 127
0 - 2
1 - 10
1 - 127
8 - 40
table#3
52 - 76
28 - 58
table#3
52 - 76
Display
Value
See Table
0 - 5
0 - 44
table#6
0 - 10
0 - 63
table#5
1 - 127
0 - 52
table#3
34 - 60
table#3
1 - 127
0 - 10
0 - 3
1 - 10
Display
Value
See Table
0 - 1
0 - 44
table#6
0 - 10
0 - 63
table#5
1 - 127
0 - 52
table#3
34 - 60
table#3
1 - 127
0 - 10
0 - 3
1 - 10
CLP-970
Control
Control
Control
Control
13