Yamaha RX-V657 - AV Receiver Servicehandleiding - Pagina 6
Blader online of download pdf Servicehandleiding voor {categorie_naam} Yamaha RX-V657 - AV Receiver. Yamaha RX-V657 - AV Receiver 49 pagina's. Av receiver/av amplifier
Ook voor Yamaha RX-V657 - AV Receiver: Productcatalogus (44 pagina's)
RX-V757/DSP-AX757/DSP-AX757SE
RX-V657/HTR-5860
The protection function worked due to a de-
fect or overload in the power supply. If the
power is turned on with the abnormality un-
solved, the protection function works in about
1 second to turn off the power.
The protection function worked due to a DC
voltage appearing at the speaker terminal.
A cause could be a defect in the amplifier. If
the power is turned on with the abnormality
unsolved, the protection function works in
about 3 seconds to turn off the power.
The protection function worked due to the
temperature limit being exceeded. Causes
could be poor ventillation or a defect related
to the thermal sensor. If the power is turned
on with the abnormality unsolved, the pro-
tection function works in about 1 second to
turn off the power.
For detection of each protection function (except I-PROTECT)
, refer to DIAG MENU No.10 AD DATA (p.42).
History of protection function
When the protection function has worked, its history is stored
in memory with a backup. Even if no abnormality is noted while
servicing the unit, an abnormality which has occurred previ-
ously can be defined as long as the backup data has been
stored.
The history of the protection function is cleared when DIAG is
cancelled by selecting PRESET RESERVED (Memory initial-
ized) of DIAG menu No.9 or when the backup data is erased.
Display during menu operation
During the DIAG operation, the menu list described in
the section of the startup screen appears on the monitor
screen and the function at work is indicated on the FL
indicator. The contents displayed during the function op-
eration are described later in the "Details of DIAG menu"
section.
32
PS PRT :000 Z
DC PRT :000 Z
TMP PRT:000 Z
各プロクテクションの検出に関しては、後述のダイアグメ
ニューNo. 10 AD DATA (42ページ) を参照してください。
プロテクションの履歴
●
プロテクションが働いた場合、履歴をバックアップして記憶していま
す。 サービスのときに異常が認められなくても、 バックアップが残って
いれば、お客様のところで起きた異常を区別できます。
ダイアグメニュー No.9 で PRESET RESERVED(メモリーの初期化)
を選んでダイアグを解除した場合、またはバックアップが消えた場合
に、プロテクションの履歴はクリアされます。
メニュー動作中の表示
●
ダイアグ中、モニター画面には起動画面の項で説明し
たメニュー一覧が表示されます。本体の FL ディスプ
レイには動作中の機能が表示されます。機能動作中の
表示内容については、後述の機能詳細で記述します。
電源電圧による原因で、プロテクションが
働いたことを示します。異常状態のままパ
ワーオンすると、約1秒後にプロテクション
が掛かり、電源が切れます。
アンプの故障でスピーカーに直流電圧が掛
かるなどが原因で、プロテクションが働い
たことを示します。異常状態のままパワー
オンすると、約3秒後にプロテクションが掛
かり、電源が切れます。
温度制限を越えた原因で、プロテクション
が働いたことを示します。異常状態のまま
パワーオンすると、約1秒後にプロテクショ
ンが掛かり、電源が切れます。