Yamaha AG-Stomp Gebruikershandleiding - Pagina 26
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Yamaha AG-Stomp. Yamaha AG-Stomp 32 pagina's. Yamaha accoustic guitar/pre-amplifier owner's manual
Ook voor Yamaha AG-Stomp: Servicehandleiding (45 pagina's), Lijst met patches (1 pagina's), (Dutch) Handleiding (32 pagina's)
Utility Mode
carry out the MIDI Bulk Out operation with a single
patch.
* After transmitting the data, the device will return to its previ-
ous condition, ready to select another patch number.
G About the MIDI Bulk In Operation
This operation is used to return data stored in an
external MIDI device, such as the YAMAHA MDF3,
etc., to the AG-Stomp.
Use a MIDI cable to connect the MIDI OUT jack on
the external MIDI device to the AG-Stomp's MIDI IN
jack.
When the Bulk Out is carried out from the external
MIDI device, the AG-Stomp will receive the bulk data.
* Use the AG-Stomp's Play Mode to receive MIDI Bulk In data.
When the MIDI Bulk In operation is carried
out, the contents of the patches in the USER
AREA will be rewritten.
Please make sure any important data is saved
before carrying out the MIDI Bulk In opera-
tion.
I External Control Settings
Just as in the "External Control Settings" section on
page 22, these settings are used to control the AG-
Stomp's volume, tone and effect parameters from a
foot controller that is connected to the EXP. PEDAL
jack or from a MIDI device that is connected to the
MIDI IN jack.
Press the [UTILITY] button and set the MIC TYPE
Select Switch to DYNAMIC 1 ("
the display).
G External Control's Operating Mode Setting
Press the [LIMITER] button and use the [UP]/
[DOWN] buttons to set the External Control's Oper-
ating Mode.
GLb
•
: The external control setting in the Utility
Mode is always available.
PrG
•
: The external control setting that is set in
the patch is available.
oFF
•
: External control is always OFF.
The following five settings are only available when
the Operating Mode above is set to "
26
CtL
" will appear in
GLb
".
G Set the External Control Number
Press the [FR 1] button and use the [UP]/[DOWN]
buttons to set a control number (
* Refer to the "External Control Settings" section (page 22).
G Set the External Controller
Press the [FR 2] button and use the [UP]/[DOWN]
buttons to set the controller type (
95
).
* Refer to the "External Control Settings" section (page 22).
G Set the Parameter to be Controlled
Press the [FR 3] button and use the [UP]/[DOWN]
buttons to set the parameter to be controlled
bAL
(
-).
* Refer to the "External Control Settings" section (page 22).
G Set the Parameter's Minimum Value
Press the [FR 4] button and use the [UP]/[DOWN]
buttons to set the parameter's minimum value (the
parameter's value when the controller is set to its
0. 0
10. 0
minimum:
-
).
* Refer to the "External Control Settings" section (page 22).
G Set the Parameter's Maximum Value
Press the [FR 5] button and use the [UP]/[DOWN]
buttons to set the parameter's maximum value (the
parameter's value when the controller is set to its
0. 0
10. 0
maximum:
-
).
* Refer to the "[External Control Settings" section (page 22).
I EXP. Pedal Settings
These settings are available when the EXP. Pedal
EP
"
" is selected as the controller in the External
Control Settings.
Press the [UTILITY] button and set the MIC TYPE
Select switch DYNAMIC 2 ("
display).
G Set the Minimum Value of the EXP. Pedal
Sets the minimum value that indicates the position
of the EXP. Pedal.
Press the [LIMITER] button and use the [UP]/
[DOWN] buttons to set the position (
You can also hold the [LIMITER] button and move
the EXP. Pedal to set the position.
* Due to the relationship between the maximum and minimum
value, a value which results in a practical range (refer to the
illustration below) of less than 128 can not be used.
1
8
-
).
EP
1
31
64
,
-
,
-
E. P
" will appear in the
0
128
-
).