aerauliqa Quantum AX Installatiehandleiding - Pagina 6

Blader online of download pdf Installatiehandleiding voor {categorie_naam} aerauliqa Quantum AX. aerauliqa Quantum AX 18 pagina's. Dmev unit
Ook voor aerauliqa Quantum AX: Installatiehandleiding (15 pagina's)

aerauliqa Quantum AX Installatiehandleiding
INSTALLATION TYPE SETTING
Installation type can be selected using JUMPER 1 between the following options: through wall or ducted. See figure 16.
TRICKLE SPEED SETTING
Trickle speed can be selected using JUMPER 2 and JUMPER 3 between the following options: 21, 29, 47 m

STANDARD CONFORMITY

2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC),
in conformity with the following standards:
Electrical Safety
EN60335-1(2008); EN 60335-2-80(2005); EN 60335-2-80/A2(2009)
Electromagnetic Compatibility
EN 55014-1(2006)+A1+A2; EN 55014-2(1997)+A1(2001)+A2(2008)+IS1(2007)
EN 61000-3-2(2006)+A1(2009)+A2(2009); EN 61000-3-3(2008).
6
/h or off. See figure 16.