Directed DBALL-GM10 XPRESSKIT Snelle referentiehandleiding - Pagina 14
Blader online of download pdf Snelle referentiehandleiding voor {categorie_naam} Directed DBALL-GM10 XPRESSKIT. Directed DBALL-GM10 XPRESSKIT 16 pagina's.
Platform: DBALL
Firmware: GM10 v. 2.08+
LED Diagnostics and Troubleshooting
LED
Status
Module Programming
Solid Red
Solid
Flashes Orange
Flashes
Flashes Green
Flashes
Solid
Solid Green 3 seconds
x3 sec.
Flashes Red 1 time
Flashes x1
Flashes Red 2 times
Flashes x2
Flashes Red 3 times
Flashes x3
Flashes Red 4 times
Flashes x4
Flashes x5
Flashes Red 5 times
Flashes Red 6 times
Flashes x6
Flashes Red 7 times
Flashes x7
Active Ground While Running
Flashes Green
Flashes
Off
Off
Inactive Ground While Running
Flashes x1
Flashes Green once
Flashes x2
Flashes Green twice
Flashes Green 3 times
Flashes x3
Description
Waiting for Can detection.
CAN and Data Bypass
successfully detected.
Cycle timeout started.
Module successfully
programmed.
Data Bypass line sleeping or not
connected.
Failed to completely remove the
key from ignition or turned the
ignition OFF without removing the
key while bypass sequence was
executing.
Cycle (programming steps 5 to 7)
timed out.
Data Bypass line sleeping or not
connected.
Programming failed.
HS CAN not detected.
SW CAN not detected.
Ground out (GWR) is active.
Normal operation
Lock function executed.
Unlock function executed.
Trunk release function executed.
Troubleshooting
Make sure that your HSCAN and SWCAN are properly
connected and press Unlock on the OEM remote.
Normal operation
Normal operation. You have now 5 seconds to finish module
programming.
Normal operation
Press Unlock on the OEM remote to activate the Data Bypass.
Cycle (programming steps 5 to 7) was done without removing
the key. Reset module and retry module programming from
step 1.
Cycle (programming steps 5 to 7) was done slower than 5
seconds. Reset module and retry module programming from
step 1.
Make sure that your connections to Data Bypass are correct,
remove key, press Unlock on the OEM remote and make sure
that the LED is flashing orange before turning the key to
ignition.
Reset the module and retry the module programming from step
1.
Check connections and click Unlock again to activate the line.
Normal operation
The Ground While Running (status) wire is incorrectly
connected. Refer to the wiring diagram to make the right
connections.
If it does not flash, the bypass module did not receive the signal.
Verify the connections between the bypass and the remote
starter module.
Rev.: 20130304
Page 14
© 2012 Directed. All rights reserved.