Zanussi ZGF 640 IT Instructieboekje - Pagina 27
Blader online of download pdf Instructieboekje voor {categorie_naam} Zanussi ZGF 640 IT. Zanussi ZGF 640 IT 28 pagina's.
Conversion from Natural Gas to LPG
IMPORTANT
The replacement/conversion from natural gas to LPG should only be
undertaken by a competent person.
It is important to note that this model is designed for use with natural gas but can be
converted for use with butane or propane gas providing the correct injectors are
fitted. The gas rate is adjusted to suit.
Method
1) Ensure that the gas taps are in the 'OFF' position
2) Isolate the hob from the electricity supply
3) Remove all pan supports, burner caps, rings and crowns.
4) With the aid of a 7mm box spanner the burner injectors can then be
unscrewed and replaced by the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely tighten down the by
pass adjustment screw. Upon completion stick the replacement rating plate
on the under side of the hob.
27