Commissioning

When the hob has been fully installed it will be
necessary to check the minimum flame setting. To do
this, follow the procedure below.
- Turn the gas tap to the MAX position and ignite.
- Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times.
If the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Remove the control knob and use a thin
bladed screwdriver to turn the adjustment
screw until the flame is steady and does not
extinguish, when the knob is turned from
MIN to MAX.
The adjustment screw may be located at the
centre of the gas tap control shaft or on the
gas tap body, left of the control shaft or
below (see diagram).
Repeat the adjustment procedure for all
burners.
Pressure Testing
Remove left hand pan support and front left
burner cap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite
another burner.
The pressure reading should be nominally
20mbar and must be between 17 mbar and
25mbar.
Turn off the burner supplies.
18
Adjustment
screw