applicable pressure adjuster on the gas supply
pipe.
ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob and the gasket.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
•
from natural gas G20 20 mbar to liquid gas,
fully tighten the bypass screw in.
•
from liquid gas to natural gas G20 20 mbar,
undo the bypass screw approximately 1/4
of a turn (1/2 of a turn for Multi Crown
burner).
6. Reassemble the gasket and the knob.
WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
•
Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
•
This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
•
Always use a correctly installed shockproof
socket.
•
Make sure that there is an access to the mains
plug after the installation.
•
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
•
There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
•
Do not let the power cable to heat up to a
temperature higher than 90° C.
To prevent contact between the cable and the
appliance below the hob use the clamps which are
on the side of the cabinet.
CONNECTION CABLE
To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H03V2V2-F T90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
7