Zanussi ZGX65424 Gebruikershandleiding - Pagina 16

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Zanussi ZGX65424. Zanussi ZGX65424 21 pagina's.

OTHER TECHNICAL DATA
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
GAS BURNERS FOR NATURAL GAS G20 20 MBAR
BURNER
Triple Crown
Semi-rapid
Auxiliary
GAS BURNERS FOR LPG G30/G31 28-30/37 MBAR
NORMAL
BURNER
POWER kW
Triple
4,0
Crown
Semi-rapid
2,0
Auxiliary
1,0

ENERGY EFFICIENCY

PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification
Type of hob
Number of gas burners
16
Gas original:
Gas replacement:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car-
tridge fuse
II2H3+
R 1/2"
3
NORMAL POWER kW
4,0
2,0
1,0
MINIMUM
POWER kW
1,4
0,45
0,33
G20 (2H) 20 mbar = 9 kW
G30 (3+) 28-30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
MINIMUM POWER kW
1,4
0,45
0,33
NOMINAL GAS FLOW g/h
INJECTOR
MARK
G30 28-30 mbar
98
291
71
145
50
73
INJECTOR MARK
146
96
70
G31 37 mbar
286
143
71
ZGX65424XS
Built-in hob
4