Clarke BRONCO 2 OIL FREE Bedienings- en onderhoudsinstructies - Pagina 6

Blader online of download pdf Bedienings- en onderhoudsinstructies voor {categorie_naam} Clarke BRONCO 2 OIL FREE. Clarke BRONCO 2 OIL FREE 8 pagina's.

Clarke BRONCO 2 OIL FREE Bedienings- en onderhoudsinstructies
Operation
Before connecting your Bronco to the mains supply, check the following :-
1.
Ensure the STOP/START switch is in the STOP position (UP for START and Down for STOP).
2.
The pressure regulator should be set to its lowest setting e.g. turned fully anti clockwise.
3.
Check that the air receiver drain valve is fully CLOSED, (finger tight only).
Now connect your air hose to the air outlet.
NOTE: A quick fit nut is supplied. Corresponding couplings are available from your CLARKE
dealer. Alternatively, the quick fit nut may be unscrewed and replaced by a standard type
straight hose connector. The hose may then be attached using a hose clip.
Attach the hose to the air tool...screwing it on directly. DO NOT use a quick fit coupling at
the air tool.
Once the hose connections are
complete, plug in and start the
compressor by pulling the STOP/
START switch upwards.
The compressor will start and
pressure will build up in the
receiver to a predetermined
maximum 116 PSI/8bar, when it
will then stop.
At this point, slowly turn the
pressure regulator clockwise to
reach the desired setting.
Remember, the air gauge
registers the receiver pressure,
NOT the outlet pressure.
Checks should now be made to
ensure there are no air leaks.
Should leaks be apparent, they
should be rectified before
continuing.
Operate the spray gun or air
tool in the normal way.
The air compressor will restart when the pressure has fallen by approximately 20 PSI and this
automatic STOP/START process will then continue as necessary to replenish the receiver.
When you have finished the job in hand, always switch OFF at the STOP/START switch on the
machine, NEVER by switching OFF at the mains.
ALWAYS
turn the pressure regulator fully anticlockwise when you have finished with the
compressor, and operate the trigger on the air tool BEFORE disconnecting the air hose.
NEVER
attempt to disconnect the air hose before checking to ensure there is no air at the
air tool.
To quickly drain the air receiver, pull and hold the ring pull on the Pressure Relief Valve
- 6 -
Technical Data
Model
Maximum Air Pressure
Air Displacement
Motor
Voltage
Rotation
Sound Power Level
Gross Weight
Receiver Capacity
Part Number
Dimensions (mm)
Please note that the details and specifications contained herein are correct at the time of going to
print. However CLARKE International reserve the right to change specifications at any time without
prior notice. Always consult the machines data plate
Accessories
Your Bronco Air Compressor can be used in conjunction with a range of optional
accessories, for inflating tyres, air brushing, stapling blowing and many other uses,
For further details, please contact your nearest dealer.
Bronco
8 BAR - 116 PSI
7 CFM (200 lpm)
1½ HP (1.1kW)
230 VAC 50hZ 1pH
2850RPM
95dBL
(Guaranteed)
WA
15.5 kg
6 Litre
2220041
375 x 200 x 435mm
- 11 -