Directed Viper 220 MAX Installatiehandleiding - Pagina 15
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Directed Viper 220 MAX. Directed Viper 220 MAX 18 pagina's. Recreational vehicle security system
This step controls whether or not the panic mode is available with ignition ON. In some provinces, there are laws
prohibiting a siren from sounding in a moving vehicle. This feature makes the system compliant with these reg-
ulations.
1-8 AUTOMATIC ENGINE DISABLE (AED) ON/OFF
AED is a full-time, passive arming starter disable that works independently of the security system. When turned
ON, the orange, ground when armed output H 1/1 will go active 30 seconds after the ignition is turned OFF. AED
does not occur in Valet mode and can be bypassed using the emergency override procedure. The transmitter can
also be used to disarm AED.
MENU # 2
2-1 SIREN/HORN OUTPUT
When using a backup APO 300 siren, this option must remain to it's default constant siren output setup. This
option can be programmed as a Horn Pulse Ouput when interfaced with an morotcycle horn circuit.
2-2 SIREN DURATION 30-60 SECONDS
It is possible to program the unit to sound for 30 or 60 seconds during the triggered sequence. Some provinces
have laws regulating how long a security system can sound. When using the 998T Bitwriter®, the siren can be
programmed to sound for any length of time ranging from 1 to 180 seconds.
2-3 NOISE PREVENTION CIRCUITRY (NPC) ON/OFF
This feature will stops repeated triggering of the same zone. If the zone is triggered three times in one hour, the
zone will be bypass for one hour, starting from the time of the third trigger. During that hour, if the system
detects a trigger on that zone again, the zone reset the one hour timer. If one hour passes and the zone has not
triggered again, the zone is activated and can trigger the system again. NPC monitors sensor inputs and the door
trigger, but does not bypass the ignition trigger at any time. If NPC is turned OFF, the system will respond to
repeated triggers on the sensor inputs and will do so indefinitely
2-5 DISARM PULSES 1 TO 5
15
© 2005 Directed Electronics, Inc. (Canada)