Clarke SHHH 2/10 Gebruiks- en onderhoudsinstructies - Pagina 9

Blader online of download pdf Gebruiks- en onderhoudsinstructies voor {categorie_naam} Clarke SHHH 2/10. Clarke SHHH 2/10 11 pagina's. Shhh air compressor

Clarke SHHH 2/10 Gebruiks- en onderhoudsinstructies
PERIODICALLY
1. Renew Air Breather every 500 hours of
operation.
2. Drain and replace the oil annually, as
follows:
(I) Slacken off the screw securing the
Compressor Head Securing Collar, shown
in Fig. 8, and remove the collar.
(iii) Pull off the Head, complete with
sealing ring.
(iii) Tilt the compressor carefully on to its side,
as shown in fig. 8, so that the oil may be
drained into a suitable container.
Dispose of the oil according to local
ordinances.
(iv) Reassemble the head ensuring the
sealing ring is in perfect condition and is
located correctly.
IMPORTANT!
USE ONLY SYNTHETIC OIL,
available from your CLARKE dealer.
3.
Check the time it takes to fill the air tank,
periodically, as follows:
(i)
Ensure the tank is fully drained and the drain tap and outlet tap firmly closed.
(ii) Start compressor and check to ensure there are no leaks, using soapy
water on all joints. Should any leak be apparent, stop the compressor,
drain the tank and rectify the leak before proceeding.
(iii) The time taken to charge the tank is 220 seconds at 20 degrees C, ± 5%
(iv) Check to ensure the cut-out pressure is 8bar (120psi), if not, consult your
Clarke dealer.
Should the tank charging time be excessive, and no leaks are apparent,
consult your Clarke dealer.
4. Check the Air Filter Should the air filter
become dirty, consult your Clarke dealer.
5. Check the Non-Return Valve
Should the tank pressure decrease for no
apparent reason, it is possible that the non-
return valve is leaking. To check, ensure the tank
is under pressure and the machine switched
OFF, then disconnect the flexible pipe (A Fig 9)
from the compressor head to the pressure valve
If air is found to be leaking, empty the tank then
dismantle the non-return valve as follows:
Fig.8
9
Fig.7
Fig.8