Aleko AR 900 Gebruikershandleiding - Pagina 13

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Aleko AR 900. Aleko AR 900 16 pagina's. Sliding gate operator

Aleko AR 900 Gebruikershandleiding
10. Solar Panel
Please refer to the manual instruction of solar panel and controller separated.

Setting Of the Control Board

WARNING: Cut off the power before change the settings. Keep away from the gate during you set the
gate opener system in case of the unexpected gate moving. Always ask the help of professional
technician /electrician if you have any question.
1. DIP Switches
The DIP switches are used to set the running time of the motor in pedestrian mode, fine adjust the soft stop
period of the motor, auto close time of the gate opener and fast change the open/close direction which is
determined by the position of the gate opener installed.
DIP Switch #1–#2: Running time of the motor in Midway Mode
DIP Switch #1: ON – 2 Seconds OFF – 0
DIP Switch #2: ON – 4 Seconds OFF – 0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled.
E.g.
DIP Switch #3–#5: Fine adjust the soft stop period of the motor
DIP Switch #3: ON – 0.5 Second OFF – 0
DIP Switch #4: ON – 1 Seconds OFF – 0
DIP Switch #5: ON – 2 Seconds OFF – 0
NOTE: Every time you restart the gate opener after power off, you should use the access control
device (such as remote, push button and etc.) to operate the gate operator to run for a complete
opening cycle and a complete closing cycle. You would achieve the soft stop in your next
opening/closing cycle. Factory default soft stop time is 1 Seconds. You can turn the DIP switches
on/off to fine adjust the soft stop time to meet your actual needs.
E.g.
Running time of the opener in midway mode is 2+4=6 seconds.
The soft stop period of the motor is 0.5+1=1.5 seconds.
12