Alemite 7889-6 Servicehandleiding - Pagina 13

Blader online of download pdf Servicehandleiding voor {categorie_naam} Alemite 7889-6. Alemite 7889-6 14 pagina's. High-pressure material pump

High-Pressure Material Pump
11. Slowly supply air pressure to the pump's motor.
12. Allow the pump to cycle slowly until the product is
once again free of air.
13. Set the air pressure to 100 psi (6.9 Bar).
14. Operate the control valve into the container
momentarily.
15. Shut off the control valve.
• Visually inspect the pump for external leaks.
• The pump should not cycle more than once or
twice in one hour.
If the pump does not stall, refer to the
Troubleshooting Chart for details.
16. Check the motor for air leakage.
If the motor leaks, refer to the Air Motor Service
Guide for details.
IMPORTANT: Make sure to reset the air
pressure to the required operating pres-
sure.
Alemite Corporation

Installation

Additional items that should be incorporated into the air
piping systems are listed in Table 5.
Part Number
338862
Moisture Separator/Regulator & Gauge Combination
5608-2
Moisture Separator
7608-B
Regulator and Gauge
5908-2
Lubricator *
Table 5 Air Line Components
* Although the air motor is lubricated at the factory, the
life of the motor can be extended with the use of a lubricator.
13
SER 7889-6
Description
Revision (3-03)