DESCRIPTION
The Model 8301 Air-Powered Diaphragm Pump is
used to transfer corrosive chemicals. The wetted
parts are polypropylene and the diaphragms are
Santoprene to resist damage from caustics, plating
liquids, brine water and other corrosive chemicals. A
silencer enclosed in the body reduces the noise. The
pump delivers a maximum capacity of fourteen
gallons per minute.
The pump has the following outstanding features:
1. Leak-Free Flange Connections
2. Side-Outlet Port Design
3. Non-Leak Manifold
4. Corrosion-Resistant Air Motor
5. Abrasion-Resistant Housing
6. Air-Valve Reset Button
7. Air Valve Requires No Lubrication
SPECIFICATIONS
Pump Ratio: .......................................................... 1:1
Air Connections:
Inlet: .................................................... 1/4" NPT (f)
Outlet: ................................................. 3/8" NPT (f)
Material Connections:
Inlet: .................................................... 1/2" NPT (f)
Outlet: ................................................. 1/2" NPT (f)
Discharge Volume per Cycle ..................... 0.025 Gal.
Maximum Size Solid: .......................................... 1/32"
Air-Supply Pressure: ................................ 20-100 PSI
Temperature Range: ................................. 32-140° F.
Net Weight: .................................................... 7.7 lbs.
670557
SERVICE INSTRUCTIONS
Diaphragm Pump
Alemite Corporation
www.alemite.com
167 Roweland Drive, Johnson City, Tennessee 37601
Figure 1: Model 8301 Diaphragm Pump
GENERAL SAFETY REQUIREMENTS
IMPORTANT: Read all instruction sheets and any
other explanatory information before beginning any
installation, operation or maintenance.
1. Check all hoses and lines for weak or damaged
condition and make sure that all connections are
secure.
NOTE: Worn or damaged parts threaten person and
property. Replace all such parts.
2. Do not use pump with any liquids not compatible
with the materials of the pump components.
3. Never exceed the maximum pressure rating of any
component in the system.
8301