SER 8571-5
Pump Indications
Pump does not cycle
Pump will not prime
Pump cycles easily
External Leaks
Product leakage visible at
Packing Nut (25)
Product leakage at bottom
of Outlet Body (28)
Internal Leaks
Pump does not prime
Revision (12-09)
1-800-548-1191-http://[email protected]
Troubleshooting Chart
Possible Problems
Pump tube jammed and/or contains loose
components
Pump leaking internally
Product source empty
1. Worn or damaged O-Ring (26)
2. Damaged Gasket (27)
1. Tube (35) not sufficiently tight
2. Damaged Gasket (34)
1. Foreign material between Valve (30)
and Plunger Body (31)
2. Foreign material between Foot Valve
(36) and Foot Valve Body (37)
3. Worn or damaged Valve (30)
4. Worn or damaged Plunger Body (31)
5. Worn or damaged Foot Valve (36)
6. Worn or damaged Foot Valve Body (37)
7. Worn or damaged O-Ring (32)
Changes Since Last Printing
Replaced Meter
Updated repair parts
Rebuild pump tube
See Internal Leaks
Replenish product
1. Replace O-Ring (26)
2. Replace Gasket (27)
1. Tighten Tube (35) into Outlet Body (28)
2. Separate Tube (35) from Outlet Body (28)
and replace Gasket (34)
Locate and eliminate source of foreign
material
Disassemble pump tube, clean, inspect, and
replace worn or damaged components