SER 9911-HA1
Assembly
NOTE: Refer to Figure 2 for component
identification on all assembly procedures.
CAUTION
Select a clean environment for all assembly pro-
cedures. Prevent contamination from foreign
material. Damage to components can occur.
Pump Assembly
IMPORTANT: Make sure to remove the
protective cover from the inlet of Pump
Assembly (1).
1. Screw Bung Adapter (4) into Cover (5).
2. Install Pump Assembly (1) into the Bung Adapter.
• Do not tighten the Bung Adapter at this time.
Cover Assembly
NOTE: The following procedures are
applicable to model 9911-HA1 only.
3. Install Grip (16) onto Handle (15).
4. Screw Nut (12) onto each end of the Handle.
5. Install the ends of the Handle into the Cover.
6. Install Lock Washer (13) and additional Nut (12)
onto each end of the Handle.
• Tighten the Nuts securely.
Revision (8-02)
10. Adjust the Pump upward approximately 1/4 "
11. Tighten the screw on the Bung Adapter securely.
12. Screw the large diameter end of Adapter (2) [with thread
13. Screw either end of Material Hose (3) into the Adapter.
14. Screw the 1/2 " -27 end of Z-Swivel (18) [with thread
15. Screw the opposite end of the Z-Swivel [with thread
16. Test/Prime the Pump assembly.
Changes Since Last Printing
Changed Bung Adapter from 326750-F1 to 326750
4
High-Pressure Portable Pump
Follower Plate Assembly
7. Place Follower Plate (9) onto the top of the product.
• With a wobbling motion, eliminate any air that may be
trapped underneath the Follower Plate. Force the
product through the hole in the center of the Plate.
8. Guide the Pump and Cover Assembly into the Follower
Plate and fit the Cover onto the container.
• Allow the Pump to descend to the bottom of the
container.
9. Secure the Cover to the container with Thumb
Screws (8).
(7 mm) from the bottom of the container.
• Make sure the pump is oriented properly.
Control Valve and Material Hose
IMPORTANT: Do not apply thread sealant to
the first two (2) threads of any connection.
Contamination can occur.
sealant] into the outlet of the Pump Assembly.
• Tighten securely.
• Tighten securely.
sealant] into the Material Hose.
• Tighten securely.
sealant] into Control Valve (17).
• Tighten securely.
• Refer to Service Guide SER 9911-1/9950-1 for details.