Clarke GSE1 Handleiding voor bediening en onderhoud - Pagina 7
Blader online of download pdf Handleiding voor bediening en onderhoud voor {categorie_naam} Clarke GSE1. Clarke GSE1 8 pagina's. Submersible pump
Ook voor Clarke GSE1: Handleiding voor bediening en onderhoud (13 pagina's)
Operation
Parts Diagram
(GSE 1 & GSE 1A)
Connect a length of delivery hose (not supplied) to the outlet spigot of the pump (GSE
and GSE1A pumps require1" hose, GSE2 and GSE2A require 2" hose). Suitable hose is
available from your nearest CLARKE dealer.
CLARKE submersible pumps are designed for use with fresh water. Avoid using your pump
with salt water, or with water containing chemicals, as these can cause damage to the
pump. If the pump does come into contact with salt or water containing chemicals,
wash it immediately. GSE pumps will handle small solids in suspension, making it suitable
for draining sumps, pits and excavations etc.
Inspect the pump regularly to check that the base inlet is clear of leaves or other debris.
Any blockage of mud or leaves can be cleared by washing the pump in fresh water, or
by using a hose to flush fresh water back through the pump outlet connector. Never
switch on the pump with the outlet connected to the mains water supply.
GSE 1A, 150A and 2A pumps incorporate an automatic float switch. As the water level
rises, the switch will float, and start the pump. As the water level falls, so will the float switch,
which in turn will switch the pump off. The position of the float switch can be adjusted by
repositioning the cable in its clip.
For the float switch to operate correctly it must be able to move freely. When putting the
pump into position, ensure there is nothing which might impede the float switch movement.
GSE pumps are fitted with automatic overload protection. If the motor overheats
(because of an obstruction in the pump, or pumping warm water, for example), it will shut
off automatically. Switch the pump off and isolate from the main electric supply, check
for blockages, and remove, allow the motor to cool down before attempting to restart.
The thermal overload will normally reset in a few minutes.
This pump should require little or no maintenance other than regular cleaning. If the
pump starts to show signs of wear or damage, contact you nearest CLARKE dealer for
advice. Do Not use the pump if there is any damage to the mains supply or float switch
cable.
Do Not attempt to repair the pump yourself, (other than to replace listed parts on page
xxx), as you may invalidate your guarantee, and damage the waterproof seal of the
pump.
If using this pump in a garden pond, please note that there is a small quantity of oil in the
pump seal. If the pump seal is worn or damaged, oil may leak out, and appear as a film
on the surface of the water. Although harmless to people, the oil must be cleared to
prevent any possible harm to pond life. Disconnect the pump from the electrical supply,
remove it from the pond, clear the oil and contact the CLARKE service department for
advice, on 020 8988 7400.
Once satisfied the pump is installed, and taking all the necessary safety and electrical
precautions as described on pages xxx, plug into the mains supply and switch ON.
NOTE:
If the pump does not deliver immediately, it is possible that an air lock exists, Leave the
pump for approximately one minute in order for the air lock to be displaced. If necessary
switch OF and On again, the pump should now deliver water, if not check all hose
connections etc.
SUITABLE HOSE, and SPARE/REPLACEMENT HOSE ADAPTERS ARE
AVAILABLE FROM YOUR NEAREST CLARKE DEALER
-9-
-6-