CTEK CHARGESTORM CONNECTED 2 Gebruikershandleiding - Pagina 10
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} CTEK CHARGESTORM CONNECTED 2. CTEK CHARGESTORM CONNECTED 2 19 pagina's.
Ook voor CTEK CHARGESTORM CONNECTED 2: Gebruikershandleiding (20 pagina's)

Technical data
POWER
Power input
TN-S: 230/400 V AC
50Hz
IT: 230 V AC 50Hz
Max 63 A (depends on
model)
Power output
AC
Connected to AC supply
Yes
network
Permanently connected
Yes
to the mains
Charging current
Up to 32 A (depends on
model)
Supply Connection
TN-S: L1,L2,L3,N,PE
IT: L1,L2,PE
Fuses
C-Characteristics.
Breaking capacity 6kA
Mode 3: 32A
Standby-usage
18-20 W
consumption
Rated frequency, f
50 Hz
n
Rated diversity factor,
1
RDF
Rated insulation
250/400 V
voltage, U
i
Rated impulse
4 kV
withstand voltage, U
imp
Rated peak withstand
6 kA
current, I
pk
Rated short-time
6 kA
withstand current, I
cw
Max prospective short-
6 kA
circuit current, I
cp
Overvoltage category
III
Technical data for RCD
Rated making and
200 A
breaking capacity, I
m
MECHANICS
Weight
Up to 24 kg (depends on
model)
Dimension
449 x 282 x 160 mm
H x W x D
Material
Front and back cover
in ABS plastic. Colored
zinc oxide metal box for
electronics.
10
MECHANICS
Ingress Protection
IP54
Ambient operation
-30°C to +50°C
temperature
Altitude
< 2000 m
Relative humidity
Up to 100 % at +25°C
Storage temperature
-30°C to +50°C
External mechanical
IK10
impact
INTERFACES
EV connector
One or two outlets Type 2 or
fixed cable of Type 1 or Type 2
Display
LED symbols
Enclosure lock
Mechanical lock with key.
Energy meter
Internal or MID-approved
depending on option.
RFID tag
Milfare 1k, Milfare 1k+, Milfare
standard
Classic.
Connectivity
3G: Frequency band:
00/850/900/1700/1800/
1900/2100 MHz, Power class
3: +24 dBm, Power class 4:
+21 dBm (EN 301 908-2 v11.1.1).
4G: Frequency band: LTE Cat-1,
B3 B8 B20 power class: 23 dBm.
Fallback GSM/GPRS/EDGE
900 MHz (Max: 2W) 1800 MHz
(Max: 1W).
COMPATIBILITY
Compliance
IEC 61851-1, IEC 62196-
2, IEC 61439-7, CE
Approval
Download the
Declaration of
Conformity from
www.ctekemobility.com
Charging method
Mode 3
Electric shock
Class I equipment
protection
Communication
OCPP 1.5 and 1.6
protocol
Pollution degree
3
Intended for use in EMC
B
Environment
User & installation instructions
SAFETY
Ground fault detection
Overcurrent and short-circuit
protection
PROPERTY
Rated current, I
n
Characteristic
Rated short-circuit capacity, I
cn
Rated service short-circuit breaking capacity, I
cs
Let-through energy, I
2
t
Part specific data
ART.NO
RATED
RATED
VOLTAGE, U
CURRENT, I
n
910-17049
230 V
16 A
910-17062
230 V
32 A
910-17050
230/400 V
16 A
910-17028
230/400 V
32 A
910-17045
230 V
16 A
910-17046
230 V
32 A
910-17047
230/400 V
16 A
910-17048
230/400 V
32 A
910-17042
230/400 V
16 A
910-17051
230/400 V
16 A
910-17063
230/400 V
32 A
910-17059
230/400 V
32 A
910-17060
230/400 V
64 A
910-17040
230/400 V
16 A
910-17091
230/400 V
32 A
910-17086
230/400 V
32 A
910-17092
230/400 V
64 A
Residual Current Device of type A. 30 mA.
DC-detector. 6 mA.
VALUE
See part specific data
C
6 kA
7.5 kA
36000 A
2
s
LEFT OUTLET
RIGHT OUTLET
nA
-
Outlet, 1 ph, 230 V, 16 A
-
Outlet, 1 ph, 230 V, 32 A
-
Outlet, 3 ph, 230/400 V, 16 A
-
Outlet, 3 ph, 230/400 V, 32 A
-
Cable, 1 ph, 230 V, 16 A
-
Cable, 1 ph, 230 V, 32 A
-
Cable, 3 ph, 230/400 V, 16 A
-
Cable, 3 ph, 230/400 V, 32 A
Cable, 1 ph, 230 V, 16 A
Outlet, 1 ph, 230 V, 16 A
Outlet, 1 ph, 230 V, 16 A
Outlet, 1 ph, 230 V, 16 A
Outlet, 1 ph, 230 V, 32 A
Outlet, 1 ph, 230 V, 32 A
Outlet, 3 ph, 230/400 V, 16 A
Outlet, 3 ph, 230/400 V, 16 A
Outlet, 3 ph, 230/400 V,
Outlet, 3 ph, 230/400 V, 32 A
32 A
Cable, 1 ph, 230 V, 16 A
Cable, 1 ph, 230 V, 16 A
Cable, 1 ph, 230 V, 32 A
Cable, 1 ph, 230 V, 32 A
Cable, 3 ph, 230/400 V, 16 A
Cable, 3 ph, 230/400 V, 16 A
Cable, 3 ph, 230/400 V, 32 A
Cable, 3 ph, 230/400 V, 32 A
CTEK E-Mobility AB