3.0 Specifications

The pulser will meet or exceed the following specifications. All specifications are
measured into a 50pF load connected to each of the two outputs with 12"
(~30cm) of Belden 8218 (75Ω) coaxial cable :
OUTPUT PULSE ELECTRICAL CHARACTERISTICS
Output Voltage
Output Voltage Adjustments
Pulse Width
Pulse Rise And Fall Time
Pulse Recurrence Frequency
Pulse Droop
Over/Undershoot
Jitter
Throughput Delay (Delay from leading edge of input
gate to leading edge of output pulse)
Maximum Duty Cycle
Maximum Average Power (Per Channel)
Pulse Output Connectors
Output Cables
GATE
Gate Source
Gate Input
Gate Rise Time
Gate Connector
GENERAL
Support Power
Dimensions (Excluding Connectors)
Weight (Approximate)
Specifications subject to change without notice
(1)
The power dissipated in each channel of the PVM-4210 when driving a
capacitive load is defined by the formula CV
capacitance, including the capacitance of the load, interconnect cable, and the
internal capacitance of the PVM-4210, V is the pulse voltage, and F is the pulse
repetition frequency (or the total pulses per second). (For these calculations, the
internal capacitance of the PVM-4210 is 125pF, and Belden 8218 cable is
21.5pf/foot.) Given the maximum power supply capability of 4W (4mA) per
channel, the maximum load capacitance, frequency and/or voltage at which the
PVM-4210 can operate can be approximated using this formula. At lower load
capacitances and/or voltages less then 950V, the PVM-4210 can operate at
Document Number 9100-0201 Rev 8
 Directed Energy, Inc. 2000-2002
(Specifications Apply To Both Output Channels)
0 to +950V ±5V (Channel 1), 0 to –950V ±5V (Channel
2)
Screwdriver-adjustable potentiometers, End Panel
<40ns to DC measured FWHM, controlled by input gate
≤15ns, 10%-90%
Single Shot to >20KHz continuous, 5MHz burst,
controlled by input gate
<1%
<5%
<1ns Shot-to-Shot
93ns typical
Continuous
(1)
4W
SHV, End Panel
12" (~30cm) Belden 8218 75Ω Coaxial Cable
External
TTL into 50Ω
<20ns
DSUB, End Panel
24VDC to 28VDC @ 600mA Maximum Current
5.5"W x 11"L x 1.75"H (140mm W x 279.5mm L x
44.5mm H )
41 Ounces (1.16 kilograms)
2
F, where C is the total load
Page 6
DEI PVM-4210
(1)