6. For fan only operation, turn the power switch to the fan only setting and set
the thermostat to its minimum setting.
7. When not in use, disconnect the heater from the mains supply. Store it in a
safe, dry, childproof location.
ADJUSTING THE ANGLE
1. Loosen both adjusting knobs.
2. Adjust to the required angle.
3. Retighten the adjusting knobs.
THERMOSTATIC PROTECTION
The Devil 2000PTC has a thermal cut
out to prevent it from overheating.
If the temperature of the front grille
gets too high the thermal cutout will
turn off the heating elements. When
the fan has cooled the unit sufficiently, normal operation will resume.
FAULTFINDING
Problem
Heater does not
operate,
although
plugged in with
the switch and
thermostat
switched on.
Heating element
glowing hot.
Heater has
failed to heat up
so only the air
fan has
operated.
Abnormal noise
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Possible Cause
Plug is loose/bad
connection.
Fuse blown or
circuit breaker trips.
No power at socket Insert the plug in a functioning socket
Input voltage too
high.
Air inlet grille is
blocked
Control switch not
set at a "HEATING"
level.
Thermostat has
tripped.
Heater is not level.
Remedy
Pull the plug out & check the
connection of the plug and socket.
Replace if necessary and investigate
cause. If fuse blows repeatedly, consult
your Clarke dealer.
Use a power supply in accordance
with the rating on the label.
Ensure the heater is kept away from
any objects which could cover the air
inlet or be drawn into it.
Turn switch to a heating level.
Turn the thermostat and listen. If there is
no CLICK and the thermostat is not
damaged, the heater will
automatically switch ON when it has
cooled down.
Stand heater on a level surface
8