TROUBLESHOOTING

Symptom
Possible cause
Clarus Sextet will not
The Clarus Sextet is not receiving
power up
power
Circuit breaker is tripped
Protection Fault LED
Indicates the internal surge
is on
protection is inoperative. This
happens when the Clarus Sextet
receives multiple surges and
sacrifices itself to protect your
electronics.
The Polarity LED is
This indicates that the power
off
cable or the wall outlet the Clarus
Sextet is plugged into has it's
polarity inverted
There is an audible
This is common, while annoying,
"thump", "click" or
it can happen when a preamplifier
"pop" coming from
or power amp's internal power
my speakers during
supply is being turned on. It will
Sextet up.
not harm the loudspeakers
CLARUS SEXTET TECHNICAL SPECIFICATIONS
AC OUTLETS TECHNICAL SPECIFICATIONS
Line Voltage
Spike Protection Modes
Spike Clamping Voltage (VMAX)
Max Surge Current (kA)
Max Spike Energy (Joule)
RoHS (Restriction of Hazardous Substances)
FILTER CIRCUITS
Analog Filter
Digital Filter
High Current Filter
PHYSICAL SPECIFICATIONS
Weight
Dimensions
CLARUS SEXTET Owner's Manual
©2020 Gordon J Gow Technologies, Inc. All rights reserved
Solution
1. Check that the power button is in the ON position
2. Check that the unit is plugged in
3. Check the outlet for power
1. Reset the circuit breaker on the side panel
2. If the Breaker continues to trip, try moving one or
more units to another Clarus Power Block, you may
be drawing too much current.
1. Disconnect your electronics from the Clarus Sextet
2. Contact your dealer for service
1. Do not operate the Clarus Sextet with an inverted
line; call an electrician to have the line repaired.
1. To minimize or eliminate "thumps", "clicks" or "pops",
program the Preamplifier or A/V Processor to turn on
before the Power Amplifiers.
6448 Pinecastle Blvd. Suite 101, Orlando FL 32809
9
120VAC 15A, 50/60Hz
L-N, N-G, L-G
L-N = 480 Joules
Up to -50db (100KHz – 6MHz)
Up to -74db (100KHz – 6MHz)
Up to -49db (100KHz – 6MHz)
13.75" Long X 3.75" High X 7" Wide
www.claruscable.com
395V
L-N = 40kA
Yes
7.8lbs.