CLAS HU 0059 Handmatig - Pagina 16

Blader online of download pdf Handmatig voor {categorie_naam} CLAS HU 0059. CLAS HU 0059 20 pagina's. 70l mixed waste oil drainer

CLAS HU 0059 Handmatig
HU 0059
70l MIXED WASTE OIL DRAINER
Tank emptying
1. Turn off all the Valves.
2. Insert ejection hook into the external disposal tank and x well.
3. Connect the compressed air with "tank air inlet/valve"
4. Slowly turn on "tank air inlet/valve" to add pressures in the tank, turn off air source once it reached desired
pressure needed for oil draining. (Safety valve will automatically release pressure when the tank pressure reach
1.0 bar/15.4PSI, now cut off air source immediately and quickly drop the tank pressure below 0.8bar/11.6PSI,
otherwise it could lead to serious incident).
5. Turn on "oil drain valve".
6. Cut off air source once oil completely drained, empty tank pressure and close all valve for completion.