ARMOUR SY001-2018-NEW Handmatig - Pagina 14

Blader online of download pdf Handmatig voor {categorie_naam} ARMOUR SY001-2018-NEW. ARMOUR SY001-2018-NEW 20 pagina's.

ARMOUR SY001-2018-NEW Handmatig
EN
Switch on the machine and allow the pressure
in the tank to build up.
As soon as the tank pressure is built up, the
motor switches off automatically.
The motor switches automatically on as soon
as the tank pressure becomes too low.
After use, switch off the machine. Vent the tank
and bleed the moisture collected in the tank.
Switching on and off (Fig. C1 & C2)

CLEANING AND MAINTENANCE

Clean the outside of the machine with a moist
cloth.
Regularly check the machine for possible
damages and leakage.
Venting and bleeding the tank (Fig. D1 - D6)
After each use the tank must be vented and the
moist collected in the tank must be bled.
Always make sure that all the moist has
been bled from the tank. Never fully close
the bleeding point if you leave the
machine in an area colder than 0 °C.
Changing the oil (Fig. E1 - E5)
The oil in the pump must be changed after every
200 hours or 3 months.
Checking the oil level (Fig. F)
The oil level in the pump must be checked before
each use.
Checking and cleaning the air filter
(Fig. G1 & G2)
The air filter must be checked every 3 months.
The air filter must be cleaned with dry air.
If necessary, the air filter must be replaced.
Let the machine cool down before
checking and cleaning the air filter.
14
TROUBLE-SHOOTING
If the machine does not work correctly, follow the
directions in the table below to solve the problem. If
you can't solve the problem yourself, contact your
dealer.
Motor does not start
Check that the on/off switch is in the "ON"
position.
Check that the power supply corresponds to
the voltage on the rating plate of the machine.
Check that the fuses in the meter cupboard are
intact.
Check that no extension cords are used that do
not comply with the applicable regulations.
Check that the work environment is not too
cold.
Compressor does not supply air
Check that the machine is switched on.
Compressor does not supply air
Check if the screw of the tank bleeding point is
tightened.
Coupling leaks air
Connect the coupling with Teflon tape wrapped
around the end.
Apply a small amount of grease to the coupling
and move the air hose several times in and out
of the coupling.
SYSTEM+