DISCOVER 14-24-2800 Bedieningshandleiding - Pagina 10

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} DISCOVER 14-24-2800. DISCOVER 14-24-2800 13 pagina's. For motive power applications
Ook voor DISCOVER 14-24-2800: Bedieningshandleiding (14 pagina's)

DISCOVER 14-24-2800 Bedieningshandleiding
8. Service & Maintenance
Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm.
This routine should be started when the batteries are first received.

8.1 Inspection

• Inspect for cracks in the battery casing
• Check battery terminals and connections to make sure they are clean, free of dirt, fluids and corrosion
• All battery cables and their connections should be tight, intact, and NOT broken or frayed
• Replace any damaged batteries
• Replace any damaged cables
• Ensure correct torque is used for the terminal bolts

8.2 Firmware Updates

Consult Discover's website for the latest firmware. If an firmware update is require, ensure this is done by a qualified installer.

9. Troubleshooting

9.1 Battery Will Not Turn On

Symptom
Description
Action
Symptom
Description
Action
Symptom
Description
Action

10. Recycling and Disposal

Batteries must not be mixed with domestic or industrial waste. Discover Advanced Energy Systems are recyclable and must be
processed through a recognized recycling agency or dealer. Please contact Discover or your servicing dealer for details.
Does the battery turn on for a short time then turns itself off?
The battery is likely in a low voltage or low SOC.
Connect to charger and turn on the battery.
Was the battery left on or stored for extended periods of time?
The battery will turn itself off at 5% SOC. If left sitting at a low SOC, the
battery may have discharged itself completely and cannot be used.
Do not use. Replace and recycle.
Does the battery appear to turn on, but has no voltage at its
terminals?
The battery fuse is likely blown.
Replace fuse. Contact Discover for support.
10