DISCOVER 14-36-3000 Bedieningshandleiding - Pagina 7
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} DISCOVER 14-36-3000. DISCOVER 14-36-3000 16 pagina's. Lithium ion battery
Copper compression lug
Shrink-wrap to
color-code the cable
Terminal surface
Terminal burnout is caused by:
• Discharge currents exceeding allowable limits
• Improper cable installation
• Improper cable sizing
• Improper terminal torque
5.5 Parallel Battery Wiring
To ensure proper balancing and load sharing between parallel batteries refer to the wiring diagram below. Lithium batteries
are very sensitive to voltage and undersized battery cables will impede battery and system performance. The thickness (cross
section) of cable used should exceed the recommended minimum for the inverter charger installation whenever possible.
Five or more batteries in parallel should be installed using a busbar configuration. In a busbar configuration all battery cable sets
should be the same length regardless of the battery's proximity to the busbar (or combiner box). Actual wiring requirements may
vary. Consult with the authority having local jurisdiction.
LOAD / CHARGER
7
M8" bolt (supplied with battery)
Lock washer (supplied with battery)
Flat washer (supplied with battery)
Battery cable lug
Ensure nothing is between
the terminal surface and the
battery cable lug
▲ NOTE!
All cable ends must be connected to battery terminals without
any washers between terminal bushings and cable ends.
▲ NOTE!
Without exception, product experiencing terminal burn out
will not be warranted.
INSTALLATION USING CABLES
LOAD / CHARGER
LOAD / CHARGER
All parallel cables should be the same length.
LOAD / CHARGER
All parallel cables should be the same length.
INSTALLATION USING BUSBAR
All cables should be the same length.
Washers ARE NOT
Washers ARE NOT
compressed!
compressed!
Terminal hardware
Terminal hardware
IS bottomed out!
IS bottomed out!
Terminal hardware
IS NOT bottomed out!
LOAD
CHARGER
CHARGER
LOAD
All parallel cables should be the same length.
LOAD
CHARGER
CHARGER
LOAD
All parallel cables should be the same length.
discoverbattery.com