ARNOLD UA 500 Gebruiksaanwijzing - Pagina 5

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} ARNOLD UA 500. ARNOLD UA 500 17 pagina's. Universal drive

ARNOLD UA 500 Gebruiksaanwijzing
4. Inspection intervals
In order to guarantee a permanently high operating safety, a brief inspection shall be
performed prior to each application (see point 2).
The complete drive is a safety relevant component and must, thus, be annually
inspected by a correspondingly trained expert according to the safety-at-work
directive (German directive: BetrSichV 2002) and DGUV directive 17.
This inspection must include the following points:
1. Check for possible damages of the housing
2. Check the eyebolts for damages and tight fit
3. Check the secure connection between upper and lower part. In this
process, particular attention must be paid to possible damages of the
security seal.
4. Check the slings (shackle / chain link and the like)
5. Check the cables, power supply units and plug-in connectors.
An inspection by an expert (e.g. TÜV) is required every 4 years. This inspection may
be carried out by the locally competent TÜV organization.
For the documentation of these cyclic inspections, an inspection book is attached to
every motor. Please consider that you put lives at risk with a defective drive. The
costs of an inspection are low compared to this danger! Please send the drive to the
company ARNOLD Lichttechnik for a more thorough inspection, if there are visible
damages that suggest a limitation of the operating safety (e.g. after a crash of the
drive).
Page 5 of 11
12/2021 REV.19