ABBINA EMG 600 IX Gebruiksaanwijzing - Pagina 8

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} ABBINA EMG 600 IX. ABBINA EMG 600 IX 20 pagina's. Electrogas

Instructions for the installer

Installation

GB
This appliance is not provided with a combu-stion
product discharge. It is recommended that it be
installed in sufficiently aerated places, in terms of the
laws in force. The quantity of air which is necessary for
combu-stion must not be below 2.0 m3/h for each kW of
installed power. See table of burner power.
Positioning (Fig. 2)
The appliance can be fitted into a working area
as illustrated on the corresponding figure. Before
positioning the hob, fit the seal X around the entire
periphery of the hole cut in the worktop.
Gas connection (Fig. 4)
Connect the appliance to the gas cylinder or to the
installation according to the prescribed standards
in force, and ensure beforehand, that the appliance
matches the type of gas available. Otherwise, see
"Adaptation to various types of gas". Furthermore,
check that the feed pressure falls within the values
described on the table: "User chacteristics".
Rigid/semi rigid metal connection Carry out the
connection with fittings and metal pipes (even flexible
pipes) so as to obtain counter stress the inner parts of
the appliance.
N.B. - when the installation has been carried out, check
the perfect sealing of the entire connection system, by
using a soapy solution.
Fig. 4
Electrical connection (Fig. 5)
Prior to carrying out the electrical connection, please
ensure that:
• the plant characteristics are such as to follow what is
indicated on the matrix plate placed at the bottom of
the working area;
• that the plant is fitted with an efficient earth connection,
following the standards and law provisions in force. The
earth connection is compulsory in terms of the law.
Should there be no cable and/or plug on the equipment,
use suitable absorption material for the working
temperature as well, as indicated on the matrix plate.
Under no circumstance must the cable reach a
temperature above 50°C of the ambient tempera-ture.
If connecting directly to the mains power supply, fit
a multi-pole switch of a suitable size for the rated
capacity with a clearance distance which completely
disconnects the power line under overvoltage category
III conditions, consistently with the rules of installation
(the yellow/green earth wir must not be interrupted). The
plug or omnipolar switch must be easily reached on the
installed equipment.
8
ISO 7/1
ISO 228/1 (FR)
Fig. 5