VIII. Troubleshooting
Problem
Cause
Pump
Air Trapped in suction
does not
line
achieve or
maintain
Foot Valve
prime
contaminated or
improperly installed
Excessive lift
Suction fittings not
properly tightened
Worn or contaminated
check valves
Kink or pinch in
suction tube
Low chemical level
Insufficient
Obstruction in suction
fluid
line
Clogged foot valve
screen
Diaphragm worn or
torn
Electronic failure
Excessive
Failure of anti-siphon
fluid
valve
Improper stroke length
Pump will
Pump not turned on or
not run
not plugged in
Electronic failure
Straighten suction line so as to eliminate high
spots
Inspect foot valve screen and assure that foot
valve is in a vertical position below fluid level
Maximum suction lift is 5 feet with water or fluids
of similar specific gravity; less with heavier
liquids such as acids. Mount pump in a lower
position relative to the chemical container.
Check fittings. Over tightening may cause
restriction. Conversely, if any leakage occurs,
pump will suck air and fail to prime.
Inspect check valves in fluid end for cleanliness.
Clean or replace as necessary.
Inspect suction tube through its full length to
assure that there are no kinks or other
restrictions
Check fluid level in chemical supply tank
Check suction line for obstructions, clogging,
kinks or pinch points
Clean or replace foot valve screen
Replace diaphragm, making sure that it is
screwed on fully to shoulder of shaft
Consult factory
Inspect or add anti-siphon valve. This is caused
when system is in a vacuum condition.
Consult factory
Check outlet with meter to assure that 95-135
VAC is present on 120V systems and that the
power supply cord is in good condition and
plugged in
Consult dealer or factory
Page 14
Remedy