CAME 9T90EN Installatiehandleiding - Pagina 10

Blader online of download pdf Installatiehandleiding voor {categorie_naam} CAME 9T90EN. CAME 9T90EN 12 pagina's. Control panel for 230 v - 400 v gearmotors

CAME 9T90EN Installatiehandleiding

10 Activating the radio command

Connect the antenna RG58 cable to the terminals and any accessory to connect to the B1-B2 output (N.O. contact) ❶.
For the AF43S / AF43SM radiofrequency cards only, position the jumper as shown according to the series of transmitters used ❷.
DISCONNECT POWER AND REMOVE THE BATTERIES, IF PRESENT. Insert the AF card on the control board.
N.B. the control board only recognises the AF card when the operator is powered again❸.
Hold down the CH1 key on the control board: the LED indicator flashes. Press a key on the transmitter to send the code. The LED will remain lit to indicate
SUCCESSFUL memorisation ❹.
Follow the same procedure with the CH2 key, associating it with another transmitter key ❺.
CH1 = channel for direct control of a panel function (OPEN ONLY, OPEN-CLOSE-REVERSE or OPEN-STOP-CLOSE-STOP, according to the selection made
on dip switches 2 and 3).
CH2 = channel for commands directed to an accessory device connected on B1-B2 or for connecting two coupled motors having a single command.
Contact rating: 5 A-24 V DC
TOP
TAM
Indicator LED
Antenna
Control board
AF card