CAME AX5024 Installatiehandleiding - Pagina 10

Blader online of download pdf Installatiehandleiding voor {categorie_naam} CAME AX5024. CAME AX5024 16 pagina's. Operator for swing gates
Ook voor CAME AX5024: Installatiehandleiding (16 pagina's)

CAME AX5024 Installatiehandleiding
RELEASING THE GEARMOTOR
This procedure must be done with the main power cut off .
The gearmotor's manual release may cause unwanted movement of the gate, if the latter has any mechanical issues or if it is not balanced.
Slide open the small door that protects the release, insert the tri-lobed key and turn it.
Connecting to the control panel
Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
For the electrical connection procedures, use the junction box and branching boxes.
ZLJ24 Control panel
Power
230V a.c. - 50/60 Hz
Connecting the 24V
d.c. delayed opening
gearmotor
Connecting the 24V
d.c. delayed closing