Sensitive Safety Edges
Configure contact CX or CY (NC), safety input for sensitive safety-edges.
See F2 (CXinput) or F3 (CY input) set to:
- C7 (sensitive safety edges with clean contact) or r7 (sensitive safety edges with 8K2 resistance), reopening during closing. When the gate is closing,
opening the contact triggers the inversion of movement until the gate is fully open again;
- edges with clean contact) or r8 (sensitive safety-edges with (8K2 resistive inputs), reclosing during opening. When the gate is opening, opening
the contact triggers the inversion of movement until the gate is completely closed.
If unused, contacts CX and CY should be deactivated during programming.
DFWN
10 11 TS 1 2 3 3P 4 5 7 CX CY
RIO WIRELESS DEVICES
Fit the RIO-CONN card into the corresponding connector on the control board.
Set the function to associate to the wireless device (F65, F66, F67 and F68).
Configure the RIO-EDGE, RIO-CELL and RIO-LUX wireless devices by following the indications shown in the folder enclosed with each accessory.
If the devices are not configured with the RIO-CONN card, the E18 error message appears on the display.
⚠ If there are any radio-frequency disturbances to the system, the wireless system will inhibit the normal operation of the operator, and this error
will show up on the display as E17.
PAIRED OPERATION OR CRP (CAME REMOTE PROTOCOL)
A B S1 GND
UTP CAT 5
A B GND
DFWN with DFI card for controlling the
connnections
10 11 TS 1 2 3 3P 4 5 7 CX CY
RIO-CONN
RIO-EDGE
Serial RS485 connection via CRP (Came Remote Protocol)
or for paired operation (see chapter called PAIRED
CONNECTIONS AND OPERATION).
Fit the RSE card.
WARNING! For the system to work properly, before
fitting the control board, you MUST CUT OFF
THE POWER MAINS and remove any emergency
batteries.