Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with current standards and
regulations. The figure shows some examples of installer's tools.
Types of cables and minimum thicknesses
Connection
Control panel power supply 230 V
Motor power supply 230 V
Flashing light
Photocell transmitters
Photocell receivers
Control and safety devices
Encoder
Antenna
N.B. : If the cables differ in length from what shown in the table, the cable cross-section is determined according to the actual current draw of the devices
connected and according to the provisions of the IEC EN 60204-1 standard.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances. When
connecting products that are not specified in this manual, please refer to the documentation provided with said products.
INSTALLATION
⚠ The following illustrations are only examples, given that the space for securing the operator and accessories varies depending on the overall dimensions.
The installation technician is responsible for choosing the most suitable solution.
The following drawings refer to a standard installation of an inward opening gate.
Cable
Cable length
type
1< 15 m
3G x 1,5 mm 2
4G x 1,5 mm 2
H05RN-F
2 x 0,5 mm 2
FROR CEI
20-22
IEC EN
50267-2-1
TWISTED
RG58
Cable length
15 < 30 m
3G x 2,5 mm 2
4G x 2,5 mm 2
2 x 1,5 mm 2
2 x 0.5 mm 2
4 x 0.5 mm 2
2 x 0.5 mm 2
max 30 m
max 10 m