Camec 042793 Handleiding voor installatie en gebruik - Pagina 5

Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} Camec 042793. Camec 042793 11 pagina's. Instantaneous gas water heater

Camec 042793 Handleiding voor installatie en gebruik

Connection Electrical Supply and Remote Control

The water heater is designed for 12 VDC (10...15V, negative ground). The power leads are
on the back of the heater and should be connected via a breaking switch to the 12 V system
of the RV. The white wire is positive (+) and the black wire is negative (see sticker). A
breaking switch is recommended for safety reasons, so the water heater could be switched
of separately.
If the leads need to be extended or any wiring is extended or replaced inside the heater, use
a minimum of 0.5 mm² wire with a temperature rating of 105°C. It is suggested that the heater
be connected to a breaker rated at 2 amps.
Never connect heater to a power converter without a battery in line or a battery charger. Do-
ing so could damage your heater and void the warranty. Be sure that the heater is connected
to a "filtered" (pure DC) circuit of the converter. To test whether the circuit is pure DC, take a
voltage reading using a multimeter set on the AC voltage scale. If the reading is more than 1
volt, the circuit is not pure DC voltage and should not be used. (See the tag on red and black
power wire on the back of heater)
5