LOW BATTERY SHUT DOWN CIRCUIT
Conditions necessary for circuit to work
1. Battery voltage
2. Key switch on
3.
CB-5 closed
4. Solenoid 2A opens with battery voltage 31.5(CCV) for more then 60 seconds. Water shut off solenoid off
with battery volt age 31.5(CCV) for more then 60 seconds.
5. Items 4 and 5 can be re -set by turning key off for about 3-5 seconds, then back on.
1
1T
12
11
(B+)
12
1,1A,1B
BATT.
IGN.
3
ACC
3
CB-5
3A
10 AMP
TO THROTTLE
CONTROL UNDER
FOOT PEDAL
1-8
LOW BATTERY SHUT DOWN CIRCUIT
36 V BATTERY BANK
A
NEW MODULE
SOLUTION FLOW
10,10A
9A
1207-1135
CONNECTOR
T206
B
17
13
15
16
14
(B-)
11
32A
(B+)
11A
(B-)
13
MODULE
REV. MTR. SOL.
10B
FWD. MTR. SOL.
11
9B
9
10
9A
16
8
18
American-Lincoln Technology
ENCORE R Troubleshooting Guide
7,7C,7H,
77,77C,77D
LOW VOLTAGE
14
R
7M,7N
7A,7B
WATER
SHUT OFF SOL.
32
(M+)
77Z
(M-)
77
SCRUB BRUSH SOL.
7,7A
2A
17
5
18
6
9
1
17
T0206/0002