Removable Fluid Seal Locking Mechanism
Camfil Fluid Seal housings are equipped with removable locking mechanisms. Under extreme working
environments, it could be possible for the locking mechanism to deteriorate and need replacement. If your
housing has been in service for an extended period of time and the locking trays are suspect to be deteriorated
or damaged, contact Camfil for replacement locking mechanisms. The following steps should be taken to
replace a fluid seal locking mechanism. To have a understanding of the various parts of the locking
mechanism, study detail illustrations No. 1 and No. 2 (next page) before replacing locking mechanism.
1. Consult your company's safety personnel before replacing any part which has been in service. Camfil is
not responsible for any personnel or procedures which include accessing a filtration housing that has been
put into service.
2. Remove the access door to gain access to the inside of the filtration housing.
3. There are two locking mechanisms installed in each filtration housing (top and bottom). Take caution when
removing the top locking mechanism, so that the locking mechanism does not fall. This could damage the
housing or injure the personnel working on the locking mechanism. Measure the distance which the 3/8"
locknuts are positioned on the locking mechanism adjustment (refer to Detail No. 2 on next page), this
dimension will be used when replacing the new locking mechanism. Remove two (2) 3/8" locknuts from
backside of adjustment studs connected to pivot arms and linkage tabs (one on top, one on bottom).
Remove two (2) 5/16" locknuts from the pivot arms (one on top, one on bottom), which is connected to the
housing with 5/16" studs. Remove the locking handle from the locking mechanism assembly and filtration
housing. Remove 3/8" locknuts from locking trays, all nuts must be removed before locking mechanism
can be removed from housing (save all locknuts for replacement installation).
4. Remove the locking mechanisms from the filtration housing. (Note: There is a nylon flat washer around
each 3/8" stud between the locking mechanism and filtration housing. These nylon flat washers
should remain around 3/8" studs, but could fall from the top studs when the locking mechanisms
are removed. Be sure the nylon washers are around studs, before replacing new locking
mechanism)
SEE DETAIL NO.2
ACCESS DOOR
CUT-AWAY VIEW
DETAIL NO. 1
LOCKING TRAY
(ONE ON TOP/ ONE ON BOTTOM)
16
3/8" LOCKING TRAY
SECURING NUTS