Command: SET,OWD,OUTH,OWD-number, output value
Example: set,owd,outh,2,15 => OWD number 2, output 1 to 4 is switched to "On
After switching the output, the new status is output as confirmation.
11.3
Data output 1-Wire Controller / 1-Wire Gateway
For the 8-fold digital output 8/8 the following data for the binary / digital inputs (push-button interface) and relay
outputs are output.
The input and output values are output as decimal values 0-254 and in a second data set binary with 0 and 1.
Each input and output has a value, which is summed up in each case.
Input pushbutton interface:
Input 1 = 1, Input 2 = 2, Input 3 = 4, Input 4 = 8, Input 5 = 16, Input 6 = 32, Input 7 = 64,
Input 8 = 128.
Relay output:
Output 1 = 1, output 2 = 2, output 3 = 4, output 4 = 8, output 5 = 16, output 6 = 32, output 7 = 64, output 8 = 128.
Data output:
1_OWD1_1|8
1_OWD1_2|10000000
1_OWD1_3|3
1_OWD1_4|00000111
Further information on the options and commands can be found in the current documentation 1-Wire Controller/1-
Wire Gateway.
12
Operating conditions
The module may only be operated at the specified voltages and ambient conditions. The device can be operated
in any position. The device is intended for use in dry and dust-free rooms. If condensation is formed, allow at least
2 hours for the unit to acclimatize.
Do not operate the module in an environment in which flammable gases, vapors or dusts are present or could be
present.
13
Assembly
The module may only be operated at the specified voltages and ambient conditions. The device is intended for
installation inside a control cabinet as a stationary device.
14
Disposal note
Do not dispose of the device within the household waste!
According to the directive concerning old electrical and electronic appliances,
electronic devices must be disposed of via the collecting points for old electronic
appliances!
15
Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics
for a part or assembly are, how to connect an external circuit, which external components or additional devices can
be connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
=> Controller No. device No._data record | Decimal value input
=> Controller No._device No._data record | Binary display input
=> Controller No._device No._data record | Decimal value output
=> Controller No._device No._data record | Binary display output
11228 V2.0 R1.0 Manual
Page 6 of 7