4.8 - THEORETICAL CALCULATIONS AND DIAGNOSTIC PROCEDURES WITH THE AID OF THE DATA
INPUT PANEL
1) Access the DIAGNOSTIC – THEORETICAL CALCULATION submenu.
2) Enter the data that concern the shape of the strip: length, width, cross-section, number of strips in series, number of
strips in parallel.
3) Enter the data and quit.
DIAGNOSTIC
1) Select the DIAGNOSTIC – ANALISYS submenu.
2) Scroll the diagnostic video-pages by using the ARROW UP – DOWN buttons. These pages contain the electrical
specifications that concern the sealing strip: maximum effective currents, resistance, full-wave effective currents,
full-wave effective power.
3) Each video page indicates 3 values that relate to the same variable under different conditions i.e.: THEORETICAL
VALUES, CALIBRATION SETTINGS, REAL TIME VALUE, in particular:
PAGE
Where IMAX stands for the maximum pulsed effective currents of the temperature controller, I0 represents the full-
wave effective current for calibration and I is the actual full-wave effective current
PAGE 2:
Where R THEORETICAL stands for the theoretical resistance of the temperature controller, R0 is the calibration
resistance and R represents the actual resistance.
PAGE 3:
PAGE 4:
PAGE 5:
THERMOSALD ISC – MANUAL QUICK START
Manual cod.: 3ES080x_V5.1_QS_EN
Includes all previous models
1:
IMAX=
I0=
I=
R THEORETICAL =
R0=
R=
I THEORETICAL =
I0=
I=
V THEORETICAL =
V0=
V=
P THEORETICAL =
P0=
P=
4) Particularlty useful information on the system conditions can be obtained
by comparing the three variables so that any malfunctioning and diagnostic
problems can be dealt with remotely.
Page Nr.
15
Rev. 2010 / 03